STANDARDS
CABLEACC
Cable glands are Manufactured and tested to the requirement of B.S. 6121
: 1989, and other standards where applicable.
Certain
Glands in our range(i.e. commercial) whilst not covered by B. S. 6121 are
generally made and tested appropriately by us as per requirement.
MATERIALS
AND FINISHED
Glands
are manufactured as standards in casting Brass (B.S.2874) and free from
blow holes, defects, spots etc. Alternatively material also used on specific
requirement.
The
standard material is unplated Brass. However on specific request platting
will be done as per requirement.
ENTRY
THREADS
Metric
threads 1.5 mm pitch are standard up to size 75mm. For size above 75mm
pitch would be 2 mm BS 3643 applies only on Brass Cable Glands comply with
BS 6121 : 1989.
The
following table gives the more popular forms available. (The table is not
a size for size comparison chart. Some taper threads e.g. NPT, BSPT may
require larger than standard entry components to accommodate the taper
dimensions.)
GLAND
SIZE |
METRIC
(MM) |
NPT |
PG |
BSP |
IMPERIAL |
Preferred |
Alternate |
Preferred |
Alternate |
Preferred |
Alternate |
16L |
16 |
3/8" |
1/2" |
11 |
9,
13.5 |
3/8" |
1/2" |
5/8" |
20S |
20 |
1/2" |
- |
13.5 |
11,
16 |
1/2" |
- |
3/4" |
20L |
20 |
1/2" |
3/4" |
16 |
11,
13.5, 21 |
1/2" |
3/4" |
3/4" |
25L |
25 |
3/4" |
1" |
21 |
- |
3/4" |
1" |
1" |
32L |
32 |
1" |
1-1/4" |
29 |
- |
1" |
1-1/4" |
1-1/4" |
40L |
40 |
1-1/4" |
1-1/2" |
36 |
29 |
1-1/4" |
1-1/2" |
1-1/2" |
50S |
50 |
1-1/2" |
- |
36 |
42 |
1-1/2" |
- |
2" |
50L |
50 |
2" |
- |
42 |
48 |
2" |
- |
2" |
63S |
63 |
2" |
- |
48 |
- |
2" |
- |
2-1/2" |
63L |
63 |
2-1/2" |
- |
- |
- |
2-1/2" |
- |
2-1/2" |
75S |
75 |
2-1/2" |
- |
- |
- |
2-1/2" |
- |
3" |
75L |
75 |
3" |
- |
- |
- |
2-1/2" |
3" |
3" |
90L |
90 |
3-1/2" |
- |
- |
- |
3" |
3-1/2" |
3-1/2" |
|
We
will mark the glands with any other threads E.G. BW-20L like BW-20L/1/2"NPT
NOTE
Other
thread types can be supplied at extra charge - details on request.
Other
diameter thread forms can be supplied but special thread may increase the
maximum across flats and across corners dimensions of the gland.
BRASS
GLAND - SELECTION CHART (FOR BS 6346 TYPE CABLES)
The
gland sizes recommended are in accordance with calculations based on cables
manufactured to BS6346 (1969) and we cannot accept any responsibility
for cables that prove to deviate materially from the nominal diameters
quoted in BS6346 (1969)
600/1000V
STANDARD COPPER CONDUCTORS PVC INSULATED WITH STEEL WIRE ARMOUR AND PVC
SHEATHED OVERALL |
CABLE
SIZE CONDUCTOR |
NUMBER
OF CORES |
NOM.
AREA
MM2 |
NEUTRAL |
1 |
2 |
3 |
3
1/2 |
4 |
5 |
7 |
10 |
12 |
19 |
27 |
37 |
48 |
1.5 |
- |
- |
16 |
16 |
- |
20S |
20S |
20S |
20 |
20 |
25 |
25 |
32 |
32 |
2.5 |
- |
- |
20S |
20S |
- |
20S |
20S |
20 |
25 |
25 |
25 |
32 |
32 |
40 |
4 |
- |
- |
20S |
20 |
- |
20 |
20 |
25 |
25 |
32 |
32 |
40 |
|
|
6 |
- |
- |
20 |
20 |
- |
20 |
|
|
|
|
|
|
|
|
10 |
- |
- |
25 |
25 |
- |
25 |
|
|
|
|
|
|
|
|
16 |
- |
- |
25 |
25 |
- |
25 |
|
|
|
|
|
|
|
|
25 |
16 |
- |
32
25 |
32
25 |
32 |
32
32 |
|
|
|
|
|
|
|
|
35 |
16 |
- |
32
25 |
32
32 |
32 |
40
32 |
|
|
|
|
|
|
|
|
50 |
25 |
25 |
32 |
32 |
32 |
40 |
|
|
|
|
|
|
|
|
70 |
35 |
25 |
32 |
40 |
40 |
40 |
|
|
|
|
|
|
|
|
95 |
50 |
25 |
40 |
40 |
50S |
50S |
|
|
|
|
|
|
|
|
120 |
70 |
32 |
40 |
50S |
50 |
50 |
|
|
|
|
|
|
|
|
150 |
70 |
32 |
50S |
50 |
50 |
63S |
|
|
|
|
|
|
|
|
185 |
95 |
32 |
50 |
50 |
63S |
63 |
|
|
|
|
|
|
|
|
240 |
120 |
40 |
50 |
63S |
63 |
75S |
|
|
|
|
|
|
|
|
300 |
150 |
40 |
63S |
63 |
75S |
75 |
|
|
|
|
|
|
|
|
300 |
185 |
- |
- |
- |
75 |
- |
|
|
|
|
|
|
|
|
400 |
185 |
50S |
63 |
75S |
90 |
90 |
|
|
|
|
|
|
|
|
500 |
- |
50 |
- |
|
|
|
|
|
|
|
|
|
|
|
630 |
- |
50 |
- |
|
|
|
|
|
|
|
|
|
|
|
800 |
- |
63S |
- |
|
|
|
|
|
|
|
|
|
|
|
1000 |
- |
63 |
- |
|
|
|
|
|
|
|
|
|
|
|
|
4-1
NOTE :
Do
not use above sizing chart for either unarmoured cables or to select protex
Gland type. Please refer to the individual product data sheet.
Selection
charts are intended as a guide. It is strongly recommended that the actual
cable dimensions are checked against the Gland dimensions to ensure a correct
selection. This is particularly important where seals are required.
CABLEACC.
and their stockist cannot accept responsibility where an incorrect selection
is made either of type or size.
4-2
NOTE :
Cable
characters shown in RED
incorporate the new circular conductors shown in BS 6346-1969 amendment
No. 3717 (OCT-1981)
HOW
TO SELECT THE CABLE GLAND
The
following is an extract from BS 6121 : Part 1, with edited additions to
assist in gland selection. The information necessary for correct Gland
selection are :
Selection
the type of cable and identify the Gland type from this catalogue.
Check
the type, size and voltage rating of the cable.
Check
ACTUAL size of cable over the inner sheath against catalogue.
Check
ACTUAL size of overall Cable diameter against catalogue.
Check
the size and type of armour or braiding, if any, against catalogue.
Check
any special environment conditions including enclosure material in relation
to corrosion.
Check
whether installation is in Hazardous Area, and Consider seal protection
for indoor/outdoor use.
Check
accessories (i.e. shrouds, earth tags, locknuts etc.)
The
table below offers guidance on the use of most popular Gland types listed
in our product details We can Cater for may application
situations which are not shown here with either standard products or, when
necessary, special variants. We would be pleased to discuss specific needs.
|
CABLE
TYPES |
Unarmoured |
Single
Wire Armour (SWA) |
|
CONDITIONS |
Outer
Seal |
No
Seal |
Outer
Seal |
Inner
Seal |
Inner
&
Outer
Seal |
I
N
D
O
O
R
S |
Clear
& Dry |
A2 |
BW |
CW |
D1W |
E1W |
External
Moisture |
A2 |
- |
CW |
- |
E1W |
Internal
Moisture |
A2 |
- |
- |
D1W |
E1W |
Dust |
A2 |
- |
CW |
- |
E1W |
Oil |
A2 |
- |
CW |
- |
E1W |
O
U
T
D
O
O
R
S |
Protected
with shroud |
A2 |
- |
CW |
- |
E1W |
Exposed |
A2 |
- |
CW |
- |
E1W |
Internal
Moisture |
A2 |
- |
- |
- |
E1W |
|
|
|
|
|
|
|
|
|
|
|
|
|
HOW
TO ORDER
Please
Specify
-
Gland
size & type
-
Quantity
of each type required
-
Material,
if other than Brass
-
Accessories
: Size, type. Quantity and material
-
Enquiry
or order number
-
State
if confirmation order
ACCESSORIES
Details
of the range of Cable Gland accessories available (earth tags, shrouds,
Locknut etc.) are given in this publication on page no.
NOTES
CABLEACC.
believes that the information about our Cable Glands given in this site
is correct at the time of going on the net, but cannot be liable for any
consequent of any error or omission. Technical changes are constantly being
made, and we reserve the right to alter the information contained in this
web-site without any notice. |